3
WIRING
3-22
n Programmable controller (NWOP40o-o)
For one-axis control of SPB (programmable controller) through pulse string outputs
Axis control can be made with the basic unit.
The form of the output pulse is command pulse and command sign.
For the programmable logic controller, refer to the operation manual or user’s manual.
Controller side
Y20
Y21
X0
X1
X2
X3
X4
M24
P24
M24
①
②
③
④
X5
X6
DC24V
⑤
⑥
⑥
Input common
Input common
Output common
Sign
Output common
Pulse output
Output common
Nearly origin signal
End of positioning
Stop command
Origin return command
Manual forward command
SPB
Basic unit: 40 points
Manual reverse command
Positioning start command
Connect the shielding wire
at both ends.