2-1) Servomotor
(1) Storage temperature
Store the servomotor in the following environment when leaving it without energization.
Storage temperature : -20 to 60 °C
Storage humidity : 10 to 90% RH (no condensation allowed)
(2) Operating environment
Operate the servomotor in the following environment.
Operating temperature : -10 to 40 °C
Operating humidity : 10 to 90% RH (no condensation allowed)
*Use the gear head in the following operating environment.
Operating temperature : 0 to 40 °C
Operating humidity : 10 to 90% RH (no condensation allowed)
(3) Mounting
The servomotor can be mounted horizontally, downward or upward. The same rule applies to the
gear head and the servomotor equipped with a brake.
The symbol in the figure indicates the mounting method coded by JEM. Description in parentheses ( )
indicates the former JEM code.
Flange-mounted
IM V1(L52) IM V3(L53)IM B5(L51)