External Input and Output PCB
The indoor unit Operation/Stop can be set by using the input connector on the PCB.
Input select
Use either one of these types of connectors according to the application. (Both types of connec-
tors cannot be used simultaneously.)
Dry contact
In case of internal power supply, set the slide switch of SW301 to "NON VOL" side.
3
Input 1
PCB
Connected device
*
+
-
3
Input 2
*
+
-
CN313
CN314
*1: The switches can be used on the following condition: DC 12 V to 24 V, 1 mA to 15 mA.
Apply voltage
In case of external power supply, set the slide switch of SW301 to "VOL" side.
1
2
3
Input 1
Power supply
PCB
Connected device
*
*
*2
+-
1
2
3
Input 2
CN313
CN314
*1: The switches can be used on the following condition: DC 12 V to 24 V, 1 mA to 15 mA.
*2: Make the power supply DC 12 V to 24 V, 10 mA or more.
- 17 -
8-1. External input
8. External input and output
WALL MOUNTED
ASUG09-12LMAS
WALL MOUNTED
ASUG09-12LMAS

Table of Contents

Other manuals for Fujitsu ASUH12LMAS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASUH12LMAS and is the answer not in the manual?

Fujitsu ASUH12LMAS Specifications

General IconGeneral
BrandFujitsu
ModelASUH12LMAS
CategoryAir Conditioner
LanguageEnglish

Related product manuals