EasyManua.ls Logo

Fujitsu ASUH12LMAS - 1. Specifications

Fujitsu ASUH12LMAS
95 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. Specifications
Type Inverter heat pump
Model name AOUH09LEAS1 AOUH12LEAS1
Power supply 208/230 V ~ 60 Hz
Power supply intake Outdoor unit
Available voltage range 187—253 V
Starting current A 3.7 6.4
Fan
Airflow rate
Cooling
CFM (m
3
/h)
789 (1,340)
Heating 789 (1,340) 842 (1,430)
Type × Qty Propeller fan × 1
Motor output W 49
Sound pressure level*
Cooling
dB (A)
54
Heating 55 58
Heat exchanger type
Dimensions (H × W × D) in (mm)
Main1: 13-1/4 × 24-9/16 × 11/16 (336 × 624 × 18.2)
Main2: 13-1/4 × 23-3/8 × 11/16 (336 × 594 × 18.2)
Fin pitch FPI
Main1: 18
Main2: 18
Rows × Stages
Main1: 1 × 16
Main2: 1 × 16
Pipe type Copper
Fin type
Type (Material) Aluminum
Surface treatment Blue fin
Compressor
Type DC rotary
Motor output W 900
Refrigerant
Type R410A
Charge
lb oz 1 lb 13 oz
g 835
Refrigerant oil
Type POE (RB68A)
Amount
in
3
(cm
3
)
20.7 (340)
Enclosure
Material Steel sheet
Color
Beige
Approximate color of Munsell 10YR 7.5/1.0
Dimensions
(H × W × D)
Net
in (mm)
14-5/16 × 19-11/16 × 19-5/16 (363 × 500 × 490)
Gross 19-1/8 × 23-15/16 × 26-3/16 (485 × 608 × 665)
Weight
Net
lb (kg)
62 (28)
Gross 73 (33)
Connection pipe
Size
Liquid
in (mm)
Ø 1/4 (Ø 6.35)
Gas Ø 3/8 (Ø 9.52)
Method Flare
Pre-charge length
ft (m)
25 (7.5)
Max. length 25 (7.5)
Max. height difference 10 (3.0)
Operation range
Cooling
°F (°C)
14 to 115 (-10 to 46)
Heating 5 to 75 (-15 to 24)
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 80 °FDB (26.67 °CDB) / 67 °FWB (19.44 °CWB), and outdoor temperature of 95 °FDB (35 °CDB) / 75 °FWB (23.9 °CWB).
Heating: Indoor temperature of 70 °FDB (21.11 °CDB) / 60 °FWB (15.56 °CWB), and outdoor temperature of 47 °FDB (8.33 °CDB) / 43 °FWB (6.11 °CWB).
Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*1: Sound pressure level
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
- 66 -
1. Specifications
OUTDOOR UNIT
AOUH09-12LEAS1
OUTDOOR UNIT
AOUH09-12LEAS1

Table of Contents

Other manuals for Fujitsu ASUH12LMAS

Related product manuals