EasyManuals Logo

Fujitsu ASUH12LMAS Design & Technical Manual

Fujitsu ASUH12LMAS
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Type
Wall mounted
Inverter heat pump
Model name ASUH09LMAS ASUH12LMAS
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 80°F (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
Heating: Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
*
1
: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB)/15°FWB (-9.44°CWB).
*
2
: Heating (5°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 5°FDB (-15.0°CDB)/4°FWB (-15.56°CWB).
Test conditions are based on AHRI 210/240 2023.
Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*
3
: Maximum current is maximum value when operated within the operation range.
*
4
: Sound pressure level:
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
*
5
: Available on Google Play
store or on App Store
®
. Optional WLAN Adapter is also required. For details, refer to the setting manual.
M condition
Model name ASUH09LMAS ASUH12LMAS
Capacity
Cooling
Rated
kW 2.64 3.52
Btu/h 9,000 12,000
Min.—Max.
kW 0.90—2.90 0.90—3.60
Btu/h 3,070—9,900 3,070—12,300
Heating
Rated
kW 3.19 3.52
Btu/h 10,900 12,000
Min.—Max.
kW 0.90—3.81 0.90—4.31
Btu/h 3,070—13,000 3,070—14,700
Heating
(17°F) *
Rated
kW 2.10 2.33
Btu/h 7,160 7,950
Max.
kW 2.88
Btu/h 9,850
Input power
Cooling
Rated
kW
0.720 1.410
Min.—Max. 0.14—1.58
Heating
Rated 0.790 0.920
Min.—Max. 0.20—1.63
Heating
(17°F) *
Rated 0.74 0.83
Max. 1.41
Current
Cooling
Rated A
3.4 6.4
Heating 3.7 4.3
EER Cooling
kW/kW 3.66 2.49
Btu/hW 12.5 8.5
COP Heating
kW/kW 4.04 3.84
Btu/hW 13.8 13.1
SEER Cooling Btu/hW 21.3 18.0
HSPF Heating Btu/hW 11.1 11.0
Power factor
Cooling
%
92.1 95.9
Heating 92.8 92.6
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 80°F (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
Heating: Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
*: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB)/15°FWB (-9.44°CWB).
Test conditions are based on AHRI 210/240 2017.
Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
- 3 -
1. Specifications
WALL MOUNTED
ASUG09-12LMAS
WALL MOUNTED
ASUG09-12LMAS

Table of Contents

Other manuals for Fujitsu ASUH12LMAS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASUH12LMAS and is the answer not in the manual?

Fujitsu ASUH12LMAS Specifications

General IconGeneral
BrandFujitsu
ModelASUH12LMAS
CategoryAir Conditioner
LanguageEnglish

Related product manuals