3. Notes and Cautions When Using ONTAP
Notes and Cautions When Updating
Notes and Cautions When Using This Product
31
• The old version is displayed when the shelf firmware version is checked.
The current version of the shelf firmware is displayed as the value for "FW Rev." when the "stor-
age shelf show -module" command is used.
Input:
Example:
In addition, for the "run -node <node_name> -command sysconfig -a" command, the current ver-
sion is displayed as follows.
Input:
Example:
● Action
If an automatic upgrade of the shelf firmware is not completed after multiple attempts, reboot
each node to update it successfully.
For the procedure to reboot each node, refer to "ONTAP 9.13.1 Setup Guide" (*1).
*1: A free Fujitsu ID is required to read this manual.
storage shelf show -module
cluster::> storage shelf show -module
Shelf Name: 1.0
Stack ID: 1
Shelf ID: 0
Shelf UID: 50:0a:09:80:0b:51:85:81
Serial Number: SHFFG1925000070
Module Type: IOM12E
Model: DS224-12
Shelf Vendor: NETAPP
Disk Count: 8
Connection Type: SAS
Shelf State: Online
Status: Normal
Modules: Module is
Monitor Is Reporting Latest Swap Operational
ID Part No. ES Serial No. is Active Master Element FW Rev. FW Rev. Count Status
--- ------------ --------------- --------- ------ --------- ------- ------- ----- -----------
A 111-03964+D0 021920015102 true true true 0240 - 0 normal
B 111-03964+D0 021919048534 true false false 0240 - 0 normal
Errors:
-------
run -node <node_name> -command sysconfig -a
cluster::>run -node cluster1-01 -command sysconfig -a
(omit ted)
Shelf 0: DS224-12 Firmware rev. IOM12E A: 0240 IOM12E B: 0240