4. Notes and Cautions for Optional Software
Notes When Using SnapCenter Plug-in for VMware vSphere (SCV)
Notes and Cautions When Using This Product
39
An error occurs during the installation of the upgrade
The following error message appears during the installation of the upgrade and the installation
may fail.
- Communication error
- Access error
Reboot the storage system and try again.
When Using SnapCenter 5.0
VMs with only FC enabled are not detected from SnapCenter
SVMs with only FC enabled may not be detected from SnapCenter. If this occurs, add manage-
ment LIFs in the SVM and perform a re-detection from SnapCenter.
Note that enabling management LIFs is not required.
Notes When Using SnapCenter Plug-in for VMware vSphere
(SCV)
When a vCenter Task of an SCV Backup Job Is Stuck at 2% after the Job Is
Completed
Phenomenon
For environments that are using SCV 4.3 to 4.6, the vCenter task of an SCV backup job may be
stuck at 2% even after the job is completed.
Action
This phenomenon has been fixed in SCV 4.7, so perform the following actions.
(1) Upgrade to SCV 4.7.
ERROR: Failed to create SnapCenter Schema. Exception: Bad handshake
ERROR: failed to create SnapCenter Schema. Exception: Access denied for user
'root'@'localhost' (using password NO)