4. Notes and Cautions for Optional Software
Notes When Using SnapCenter Plug-in for VMware vSphere (SCV)
Notes and Cautions When Using This Product
39
• An error occurs during the installation of the upgrade
The following error message appears during the installation of the upgrade and the installation
may fail.
- Communication error
- Access error
Reboot the storage system and try again.
When Using SnapCenter 5.0
• VMs with only FC enabled are not detected from SnapCenter
SVMs with only FC enabled may not be detected from SnapCenter. If this occurs, add manage-
ment LIFs in the SVM and perform a re-detection from SnapCenter.
Note that enabling management LIFs is not required.
Notes When Using SnapCenter Plug-in for VMware vSphere
(SCV)
When a vCenter Task of an SCV Backup Job Is Stuck at 2% after the Job Is
Completed
● Phenomenon
For environments that are using SCV 4.3 to 4.6, the vCenter task of an SCV backup job may be
stuck at 2% even after the job is completed.
● Action
This phenomenon has been fixed in SCV 4.7, so perform the following actions.
(1) Upgrade to SCV 4.7.
ERROR: Failed to create SnapCenter Schema. Exception: Bad handshake
ERROR: failed to create SnapCenter Schema. Exception: Access denied for user
'root'@'localhost' (using password NO)