3. Notes and Cautions When Using ONTAP
Notes and Cautions When Updating
Notes and Cautions When Using This Product
30
When Upgrading to ONTAP 9.12.1 P4 or ONTAP 9.13.1
After the upgrade to ONTAP 9.12.1 P4 or ONTAP 9.13.1, the shelf firmware fails to be automatically
updated so the update process may repeat.
● Phenomenon
• If an automatic upgrade of the shelf firmware is attempted multiple times, the following events
are repeatedly recorded in the EMS.
• If there is a node being updated due to repeated attempts of a shelf firmware update, "running"
is displayed as follows.
Input:
Example:
[cluster-01: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0a.shelf0 has
downrev firmware.
[cluster-01: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0a.shelf1 has
downrev firmware.
[cluster-01: dsa_sfu: sfu.firmwareDownrev:error]: Disk shelf firmware needs to be
updated on 2 disk shelves.
[cluster-01: dsa_sfu: sfu.downloadStarted:info]: Update of disk shelf firmware
started on 2 shelves.
[cluster-01: dsa_sfu: sfu.downloadSummary:info]: Shelf firmware updated on 2
shelves.
set advanced
storage shelf firmware show-update-status
cluster::> set advanced
Warning: These advanced commands are potentially dangerous; use them only when
directed to do so by Fujitsu personnel.
Do you want to continue? {y|n}: y
cluster::> storage shelf firmware show-update-status
Update In-Progress
Node Status Count
------------------ ------- -----------
cluster-01 running 10
cluster-02 idle -
2 entries were displayed.