RX300 S3 Service Supplement 43
Replacement routines Replacing the IDTemp Combo
4.9 Replacing the IDTemp Combo
This board includes two important system components:
EEPROM for the chassis ID and Ident number of the server
temperature sensor for monitoring the environment temperature
The data for the EEPROM, and the current temperature values as well, are
transmitted to the system board via the connected I2C bus.
The IDTEMP combo must be correctly installed in order to monitor the temper-
ature correctly, enable ServerView to display the correct system picture and to
install the server using ServerStart.
Ê Open the server as described in the section “Preparation” on page 17.
Ê Remove the fan box.
I Information to this item you will find in the section “Fan box” on
page 38’.
Figure 34: Removing the IDTemp Combo with its holder
Ê Remove the IDTemp Combo from the holder.