Examples
Error executing AddJob; the list contains error codes for each component.
Event.0=StartFlash
SubEvent.0=Count
CompCount.0=1
NoError.0=1
Event.1=StartFlash
SubEvent.1=Result
ObjTypeName.1=MAH3091MC
ObjName.1=Disk:PCI1.11.1.SCSI0.0.0
OldVersion FW.1=5207
NewVersion FW.1=5208
LastCommand.1=AddJob
Error.1=91
ErrorText.1=ERROR[91] couldn't build control file
name
Error executing StartUpdate; a component list is not available because the
error refers to the StartUpdate GFI request.
Event.0=StartFlash
SubEvent.0=Error
CompCount.0=2
LastCommand.0=StartUpdate
Error.0=12
ErrorText.0=ERROR[12] flash file missing
(cannot copy file)
If no obsolete components exist (compared with the repository), only the
header is shown.
Event.0=StartFlash
SubEvent.0=Count
CompCount.0=0 number of obsolete FW versions = 0
NOERROR.0=0