2. 30 kW TR UP modification
3
2. 30 kW TR UP Radar
2.1 Necessary Parts
Table 2.1 Parts list
Necessary parts Q’ty Modification No.
RFC cover: 37S 1 pc. Fig. 2.1
Spacer for RFC cover: M3 x 15 7 pcs. Fig. 2.1
EMI core: RFC13 1 pc. Fig. 2.1
EMI core: RFC8 2 pcs. Fig. 2.1
Cable tie: 100 mm 6 pcs. Fig. 2.1
Jumper wire: 140 mm 1 pc. Fig. 2.2
EMI core: RFC10 1 pc. Fig. 2.3
Cable clump 1 pc. Fig. 2.3
M3 x 12 screw 1 pc. Fig. 2.3
Microwave absorbent: 150 x 60 1 pc. Fig. 2.4
2.1 Addition of RFC cover
1. Set up the RFC cover and cable ties as shown in Fig. 2.1.
2. Replace the fixing screws with the spacer.
3. Disconnect the plug P803.
4. Add EMI cores to the cables as shown in Fig. 2.2.
Fig. 2.1 RFC cover
RFC8 (J802)
RFC13
(J803, J804, J805)
Fig. 2.2 Add EMI core