EasyManua.ls Logo

Furuno FAR-2807 Series - Setting of AD-100 or GC-10

Furuno FAR-2807 Series
563 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.7 Setting of AD-100 or GC-10
4-42
4.7 Setting of AD-100 or GC-10
This is the setting for AD-100 or GC-10 (64P1106-99).
This board outputs both of the AD format and the NMEA data. Basically make the
setting so as to use data in the AD format.
- For input in AD format
Set the transmission cycle to 25 msec.
- For input in NMEA data
Set to Ver-2.0, 38,400 bps and transmission cycle to 25 msec.
For FURUNO technical information on the AD converter, refer to FQ4-2004-016.
Fig. 4.7.1 Connection of GC-10
The related setting:
Table 4.7.1 Related Setting
Set item
For data input
in AD format
For input of NMEA data
1: HDG SOURCE AD-10 SERIAL
[HDG] icon menu
2: GC-10 SETTING Set HDG value
Jumper plug of
terminal board
[J656]: See page.4-40
(38.4 kbps)
J5(3p)
J7(5p)
J8(5p)
J9(5p)
J4(5p)
J603(GC-10)
J656(HEADING)
J608
(AD CONVERTER)
J1(14p)
J6(4p)
R1/R2
S1/S2/S3
Gyro compass
AD DATA/CLK
GC-10
Terminal p.c.b
GC Control
RPU-013
NMEA Ver-2.0
HDT/38.4kbps/25msec
or

Table of Contents