3. 30 kW TR Down modification
6
3. 30 kW TR DOWN Radar
3.1 Necessary Parts
Table 3.1 Parts list
Necessary parts Q’ty Modification No.
RFC cover: 37SW 1 pc. Fig. 3.1
Spacer for RFC cover: M3 x 15 9 pcs. Fig. 3.1
Shield 350 mm for IF-RFC cable 1 pc. Fig. 3.2
Metal clump: 9 mm 1 pc. Fig. 3.2
EMI core RFC: 10 1 pc. Fig. 3.2
EMI gasket: 170 mm 2 pcs. Fig. 3.3
EMI gasket: 90 mm 2 pcs. Fig. 3.3
Jumper wire: 360 mm 1 pc. Fig. 3.4
Microwave absorbent 1 pc. Fig. 3.6
Cable tie 100 mm 2 pcs.
3.1 Addition of RFC cover
1. Replace the fixing screw with the spacing nuts of the RFC cover.
2. Disconnect the plug P803.
3. Fix the RFC cover by the screws. (For inner most two, use spacer instead of screw.)
4. Connect J803.
Fig. 3.1 RFC cover added