3. 30 kW TR Down modification
7
3.2 Shielding to IF-RFC interconnection cable
1. Add the shield to IF-RFC cable.
2. Use metal clump to ground the shield at both sides.
3. The shield should not be applied to the cable inside EMI core.
4. Tighten the both ends of shield with the cable tie and then protect it with vinyl tape.
Fig. 3.2 shield to IF-RFC cable
3.3 EMI gasket for IF amp case
Add an EMI gasket to the IF amp case.
EMI gasket 175 mm
EMI gasket 85 mm
Fig. 3.3 EMI gasket