2.2 Scanner Unit
2-18
Fig. 2.2.13 IF AMP Board, 03P9335
A
J823 (IF Output)
J824 (IF Input)
Fig. 2.2.14 MD Board, 03P9244A/B
VR1 (Power)
60 MHz IF Output
03P9244A: X band 12 kW
03P9244B: X band 25 kW
03P9244E: S band 30 kW
Used to adjust magnetro
n
current at factory.