4.4
Initialize Setting
Initialize Setting Initialize Setting
Initialize Setting
4-38
4.4.14 INS
INITIALIZE -> 8: OTHER -> 5
This is for the selection of the port of the INS (Integrated Navigational System).
Set [Menu] -> 0 ->6 -> 2:TTM OUTPUT to “REL” or “TRUE”.
Table 4.4.11 TTM OUTPUT and INS Setting
TTM OUTPUT
setting
INS
setting
Port
OFF REL TRUE OFF SRIAL LAN
IN/OUT DATA
J619: ECDIS X X X OUT TTM
J620: TRACK CONTROL X X X IN/OUT ECDIS
*
LANNETWORK
X X X IN/OUT ECDIS
*
* ECDIS-related sentence
ECDIS-related input sentence (INS)
GLL, GGA, FUGLL, DTMOSD, ZDA, DPT, MWV, PAESP, PAESC, PAESF,
PLSPL, PLSPS, PAESW, PAESN
NAV data-related input sentence (NAV)
GGA, GLL, RMC, RMA, BWR, BWC, RMB, ZDA, DPT, DBT, DBS, MTW,
MWV, VWT, VWR, VDR, WPL, RTE, DTM, VBW, VHW, VTG, HDT
Output sentence
OSD / PAESP / TTM* / PFEC, RAssd / RSD
* To output TTM data
Set [Menu] -> 0 ->6 -> 2:TTM OUTPUT to “REL” or “TRUE”.
Note:
By the above setting, the items of [Menu] -> 2 -> 7 are changed.
- TTM OUTPUT: REL or TRUE
[Menu] -> 2 -> 7: [INS MARK]
Make the setting of USER CHART, CURVED EBL, CHART SYMBOL,
NOTE BOOK and RUTE associated with INS.
- TTM OUTPUT: OFF
[Menu] -> 2 -> 7: [BARGE MARK]
Make the setting of ON/OFF, BARGE MARK SIZE and ARANGEMENT for
the display of BARGE MARK.