Following tables show normal value in RF Monitor display.
Keystroke: MENU>9>8>2 (Selftest)
FAR-2827W, 2x27
Monitor Item L: 48NM M2: 6NM M1: 3NM S2: 1.5NM S1: 0.125NM
TUNE IND 1.6 1.6 1.5 0.7 1.0
R MONITOR 3.9 3.9 3.9 3.9 3.9
MAG CURRENT 4.6 3.6 2.8 2.5 1.9
HEATER 1.4 1.4 1.7 1.7 1.7
TUNE OUT 16.0 16.0 16.3 16.2 16.2
FAR-2837SW, 2x37S
Monitor Item L: 48NM M2: 6NM M1: 3NM S2: 1.5NM S1: 0.125NM
TUNE IND 1.5 1.7 1.6 1.4 2.6
R MONITOR 4.3 4.3 4.3 4.3 4.3
MAG CURRENT 4.3 3.9 3.2 2.7 2.0
HEATER 1.5 1.5 1.5 1.8 1.8
TUNE OUT 9.9 10.0 10.1 10.1 9.8
Remedy
Modify the RF unit as described in the attached sheet. RF unit modification kit is
available with the following code number
Model Code Number
12 kW/25 kW X-band (TR UP and TR DOWN) MOD-FAR-001
30 kW TR UP MOD-FAR-002
30 kW TR DOWN MOD-FAR-003
Factory modification
From March 2005