INSTRUCTION MANUAL
SETTING AND ADJUSTMENTS
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
Model FMD-3200/FMD-3200-BB/FMD-3300/FCR-2119-BB/
FCR-2129-BB/FCR-2139S-BB/FCR-2819/FCR-2829
FCR-2839S/FCR-2829W/FCR-2839SW
This manual is solely for use by the installer. Under no
circumstances shall this manual be released to the user.
The installer shall remove this manual from the vessel
after installation.
This manual contains no password data. Obtain password
data from FURUNO before beginning the installation.

Table of Contents

Other manuals for Furuno FMD-3200-BB

Question and Answer IconNeed help?

Do you have a question about the Furuno FMD-3200-BB and is the answer not in the manual?

Furuno FMD-3200-BB Specifications

General IconGeneral
Display TypeLCD
Screen Size12.1 inches
Resolution1024 x 768 pixels
Input Voltage24 VDC
Weight4.5 kg
Display Size12.1 inches
TypeECDIS
Power Supply24 VDC
TouchscreenYes
Operating Temperature-15°C to +55°C
InterfacesEthernet, USB
CertificationsIMO, IEC

Summary

Setting and Adjustments

Instruction Manual

The primary title of the document.

Introduction

Manual Contents and Preparation

Details the manual's scope, necessary preparation, and trademarks.

Silent Mode Operation

Instructions for activating and deactivating silent mode for audio alarms.

1. INITIAL SETTING AND ADJUSTMENT

1.1 How to Access the [Common Installation Setting] Menu

Explains how to access the Common Installation Setting menu via LAN or control unit.

1.2 [Basic Setting] Menu

Details on configuring basic settings like Equipment ID, monitor, and printer.

1.3 [Own Ship Setting] Menu

Enters ship parameters, sensor positions, and own ship information.

1.4 [Installation Parameters] Menu

Sets signals and input data for various sensors like GPS, Radar, etc.

1.4.1 Sensor Setting

Configures sensor data types, integrity, and connection for GPS, VDR, etc.

1.4.2 Processor Unit Configuration

Defines the active processor units (ECDIS, Chart Radar) and their combinations.

1.4.3 Activating Connection with FAR 2xx8 Radar (ECDIS Only)

Establishes connection with FAR-2xx8 series radar processor units for ECDIS.

1.4.4 Sensor Adapter Configuration

Configures Sensor Adapters, including their serial input/output and digital settings.

1.4.6 Radar Connection Box Configuration (ECDIS Only)

Configures connection boxes (RCB-002) for displaying echoes from non-Furuno radars.

1.4.7 Monitoring of HUB

Sets up monitoring for HUB connection status and alerts.

1.4.8 Signal and Port Setting for External Equipment

Configures serial I/O, analog input, and HUB ports for external equipment.

1.4.9 Customized Sensor Setting

Allows adding or editing custom sensor types and manufacturers.

1.4.10 Shuttle Ferry Mode Activation (Chart Radar Only)

Configures external switch for shuttle ferry mode as an 'Other Sensor'.

1.5 [CCRS] Menu

Menu for configuring Centralized Communication and Reporting System.

1.5.1 Data Source Selection

Procedure for selecting data sources and setting priorities for CCRS.

1.5.2 Transmission Group Setting

Adjusts transmission group settings for IEC61162-450 compatible sensors.

1.5.3 CCRS Setting Window

Configuration for NSR sentence output from CCRS.

1.6 [TCS] Menu

Adjusts settings for the Track Control System (TCS) and compatible autopilots.

1.6.1 Preparation for TCS

Notices for sensor data connection and dongle confirmation for TCS.

1.6.2 Setting TCS for Autopilot

Step-by-step guide to setting up the TCS for autopilot connection and configuration.

1.6.3 Setting the Navigation Parameter

Sets navigation parameters like ship speed, turning radius, and forwarding distance.

1.6.4 Multiple ECDIS and Autopilot Control

Manages manual switching of ECDIS units for autopilot control.

1.6.5 Detail Settings for TCS

Detailed TCS configuration options for rules, monitoring, and track control.

1.6.6 Filter Setting Window

Sets tolerance values for sensor integrity checks.

1.6.7 Other Setting Window

Configures data format for route data output to external equipment.

1.7 AMS Menu

Sets up the Alert Management System interface and operating mode.

1.7.1 AMS Mode Operation

Configures alert monitoring interval, buzzer patterns, and transfer categories.

1.7.2 Master/Backup AMS Setting

Assigns master and backup AMS units for alert data output.

1.7.3 Alert Transfer Setting

Configures alert groups and transfer settings to navigational equipment.

1.7.4 Other Setting Window

Provides settings for Category C alert silence, BR-2000 connection, and ACK signals.

1.7.5 Import and Export AMS Menu Settings

Procedures for importing and exporting AMS menu settings.

1.8 Alert Define List Menu

Manages alert groups and definitions for external equipment.

1.8.1 Alert Group Setting

Allows creation, deletion, and sorting of alert groups.

1.8.2 Add Alert Group

Step-by-step guide to creating a new alert group with specific alerts.

1.8.3 Edit Alert Group

Procedure for editing existing alert groups and adding/removing alerts.

1.8.4 Delete Alert Group

Steps to delete alert groups from the system.

1.8.5 Alert Definition Setting for Each Equipment

Enables/disables and configures alerts for specific equipment types.

1.8.6 Add Alert Definition

Guide to adding new alert definitions, including name, ID, and priority.

1.8.7 Edit Alert Definition

Details on editing alert definitions, including priority and escalation settings.

1.8.8 Delete Alert Definition

Procedure for deleting specific alert definitions from the system.

1.10 Save and Sync Menu

Handles configuration consistency checks, saving, and synchronization.

1.10.1 Consistency Check and Save Configuration

Steps to perform consistency check and save the current system configuration.

1.10.2 Save Configuration Data to Medium

Instructions for saving configuration data to external media like USB or PC.

1.10.3 Load Configuration Data

Instructions for loading configuration data from external media.

1.11 System Monitor Menu

Displays system information for processor units, monitors, and adapters.

1.12 Software Update Menu

Procedure for updating the software of processor units, radar units, and control units.

1.13 Factory Test & Default Menu

Performs factory tests and restores system default settings.

1.14 Conning Menu

Configures the layout and data displayed on the conning display.

1.14.1 Select Data Source

Selects data sources for display components on the conning screen.

1.14.2 Advanced Settings Window

Provides advanced configuration options for conning display components.

1.16 Set Forwarding Distance

Sets the forwarding distance parameter used for ship steering control.

1.17 Synchronization With Ship’s Clock

Activates synchronization of the system clock with the ship's clock.

1.18 Change Data Color by Integrity

Customizes data display color in Sensor Information Box based on integrity check results.

2. SETTING FOR SENSOR ADAPTER

2.1 Set Equipment ID

Procedure to set the unique Equipment ID for the Sensor Adapter.

2.2 Save Log File

Instructions for saving the Sensor Adapter log file to a PC for status checking.

2.3 Update Firmware (MC-3000S)

Guide to updating the firmware program of the MC-3000S Sensor Adapter.

2.3.1 Activate Maintenance Program

Steps to activate the maintenance program for firmware updates.

2.3.2 Confirm Firmware Program Version

Procedure to verify the current firmware version of the Sensor Adapter.

2.3.3 Update Firmware Program

Detailed steps for updating the firmware program using FTP.

3. DUAL GYRO SYSTEM (ECDIS Only)

Enable Dual Gyro System

Enables the dual gyro system by configuring gyro selectors and serial ports.

4. HUB-3000 IGMP QUERIER SETTING

HUB-3000 IGMP Querier Configuration

Steps to configure the IGMP querier of HUB-3000 for network construction.

5. RAYTHEON ANSCHUTZ AUTOPILOT NP-5400

5.1 Installation Parameters

Sets installation parameters for the Raytheon Anschutz Autopilot NP-5400.

5.1.1 HCS Setting

Configures the HCS (Hull Control System) setting for the autopilot.

5.1.2 NP-5400 Alert and Backup Navigator Setting

Configures alerts and backup navigator settings for the NP-5400 autopilot.

5.1.3 BNWAS Setting

Provides necessary settings for BNWAS when installed with AMS.

5.1.4 Serial Ports Configuration

Configures serial port connections for TCS, alert, speed, and position on the NP-5400.

5.2 TCS Port Setting

Sets communication sentences between FMD and NP-5400 for TCS application.

5.3 NP-5400 Alert Port Setting

Connects FMD to NP-5400's MOXA LAN-Serial Converter for alert settings.

5.4 NP-5400 Backup Navigator Port Setting

Connects FMD to NP-5400's MOXA LAN-Serial Converter for backup navigator.

5.5 Position and Time Ports Settings

Configures position and time ports for transmitting data to the NP-5400.

5.6 Speed Port Setting

Sets the speed port for transmitting speed data from FMD to NP-5400.

5.7 Backup Navigator Setting

Configures backup navigator (ALR sentence) output when BNWAS is connected.

5.8 Save and Sync

Saves and synchronizes settings after completing chapter configurations.

APPENDIX 1 EQUIPMENT ID List

APPENDIX 2 SUBSYSTEM

APPENDIX 3 RCB-002 IP ADDRESS SETTING

RCB-002 IP Address Configuration

Steps to set IP addresses for multiple Radar Connection Box RCB-002s.