22
Wiring Information
Pin No.
Color
Function
7
Shield
Shield
6
Black
GND
5
Red
12V_OUT
4
Green
RD1-B [(-)NMEA1 IN]
3
Yellow
RD1-A [(+)NMEA1 IN]
2
Blue
TD1-B [(-)NMEA1 OUT]
1
White
TD1-A [(+)NMEA1 OUT]
2.3.3. DATA 2 Description
The DATA2 Port can be used to connect additional NMEA 0183 instruments. Use the
included cable assembly FRUDD-18AFFM-L180 (P/N 000-164-608). This included Pig-
Tail Cable has an 18-Pin connector. DATA2 also provides additional Input/Output
interfacing connections (Buzzer, Event …). For example, a MOB Contact Closure Input
may be connected to PIN 15 and 11*.
*Note that any MFD will interface to virtually any MOB System or Event switch (Point
Save) contact closure signal using these pins.