1. MOUNTING
1-3
7. Attach the flush mount fixture to the TZT16F with hex bolts.
8. Fasten each wing bolt (4 pcs.) so that the protector for screw touches the mount-
ing panel.
9. Fasten the wing nuts tightly.
Note: Use of excessive torque when fastening the wing bolts can cause the flush
mount fixture to tilt or warp. Check that the flush mount fixtures and wing bolts are
not tilted or warped, referring to the following examples.
Set TZT16F to the cutout.
Attach the flush mounting
plate to the TZT16F.
Attach the flush mounting
plate to the TZT16F.
①①
②②
Wing bolt
Wing nut
Flush mounting fixture
Protector for screw
Mounting panel
TZT unitTZT unit
Flush mount fixture is fixed at right angle. Flush mount fixture is warped, wing bolts are tilted.