3. HOW TO SET UP THE EQUIPMENT
3-8
[Initial Setup] menu - [CALIBRATION]
[Initial Setup] menu - [DATA DAMPING]
[Initial Setup] menu - [FUSION]
[Initial Setup] menu - [BROWSER INSTALLATION]
[Initial Setup] menu (Other menu items)
Menu item Description Options (setting range)
[Heading] Offset heading data. -180.0° to +180.0°
[Speed Through
Water]
Calibrate speed data. Enter amount in percentage. -50% to +50%
[Wind Speed] Offset wind speed data. Enter amount in percentage. -50% to +50%
[Wind Angle] Offset wind angle data. -180° to +180°
[Sea Surface
Temperature]
Offset sea surface temperature data. -10°C to +10 °C
Menu item Description Options (setting range)
[COG & SOG] Set data damping time. The lower the setting
the faster the response to change.
0 to 59 (seconds)
[Heading]
[Speed Through Water]
[Wind Speed & Angle]
[Rate of Turn]
Menu item Description Options (setting range)
[Connect to Fusion] Connects to your Fusion equipment.
[Fusion Auto Volume] Set to [ON] to allow the TZT16F unit to con-
trol the FUSION volume. Volume is adjusted
according to vessel speed.
[ON], [OFF]
[Minimum Speed] Set the minimum speed threshold. Exceed-
ing this speed activates volume auto control.
0.0 (kn) to 98.9 (kn)
[Maximum Speed] Set the maximum speed threshold. 0.1 (kn) to 99.0 (kn)
[Volume Increase] Set the amount of extra volume to output
when the vessel reaches the [Maximum
Speed] setting.
10% to 50%
Menu item Description Option (setting range)
[FAX30 Browser] Show the Facsimile Receiver FAX-30 display.
[FA30 Browser] Show the AIS Receiver FA-30 display.
[FA50 Browser] Show the AIS Receiver FA-50 display.
Menu item Description Option (setting range)
[Chart Master Device] Set to [ON] to use this unit as the master, [OFF] to use this unit as a slave.
[System ID] The system ID for this device within the network.
[IP Address] IP address for this unit within the network.
[Quick Self Test] Displays various details regarding the TZT16F unit, radar and fish finder.
[Certification Mark] Displays relevant certification for this equipment.
[Service] Requires login password. For the service technician.
[Update Network
Equipments]
For the service technician.
[Event Input Configu-
ration]
Set the function for the event switch. [OFF], [Event], [MOB], [Ferry]