It selects the throttle input operation. Pushing
data+ or – key, the mode is changed
Optimize:
GY701 operates the throttle input signal as optimize.
No need to consider the throttle curve setting on the
transmitter.
Fixed:
The fixed throttle input is utilizing related by the
revolution. It is recommended for the electric motor.
Tx.Curve:
GY701 uses the exact throttle input from the trans-
mitter. The throttle curve setting on the transmitter
is required. When the Rev.Lmt mode is selected, this
mode should be selected.
(7) Revolution change up delay
default:
8
range:
2
20
It sets the delay at the revolution changed from
low to high. Pushing data+ or key, the value is
changed.
(8) Revolution down delay
default:
10
range:
2
20
It sets the delay at the revolution changed from
high to low. Pushing data+ or key, the value is
changed.
(9) Start delay
default:
5
range:
2
20
It sets the delay at the starting up the governor.
Pushing data+ or – key, the value is changed.
(10) Low limit at hovering
default:
25 %
range:
0
80 %
It sets the throttle low limit at hovering revolution
to avoid too much lean the carburetor. Pushing
data+ or – key, the value is changed.
(11) Low limit at idle up
default:
45 %
ranges:
10
80 %
It sets the throttle low limit at idle up revolution to
avoid too much lean the carburetor. Pushing data+
or – key, the value is changed.
(12) Governor data reset
It resets the governor parameter to default setting.
The “Exec.??” is displayed by pushing data + or
key for conrmation. Push data+ or key again,
the reset process is done and displayed “-Exec.—“