Flex 4 & Flex 8
Microprocessor Based
Fire Alarm Control Panels
INSTALLATION and OPERATION MANUAL
Notice: All information, Documentation, and Specifications contained in this manual
are subject to change without prior notice by the manufacturer.
©1999 by The Gamewell Company Part Number 71954
Issue B 07/19/2001
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Gamewell Flex 4 and is the answer not in the manual?

Summary

Introduction

Overall Features

Details the capabilities and configurations of the Flex 4 and Flex 8 Fire Alarm Control Panels.

General Notes and Definitions

System Components

Models

Lists and describes the different models of Fire Alarm Control Panels and optional modules.

Accessories

Details optional accessories such as remote annunciators and resistors.

Batteries

Specifies the required battery models and capacities for the system.

Mechanical Installation and Dimensions

Modules Mounting Locations

Module Settings

Main Fire Alarm Module Settings

Configuration details for the main fire alarm control panel, including jumpers and DIP switches.

Circuit Expander Module (CEM) Settings

Configuration settings for the CEM module, including Class A/B selection and DIP switches.

Relay Module (RY4 or RY8) Settings

Details on configuring RY4/RY8 relay modules, including jumper settings for control.

Digital Alarm Communicator Module (DACT) Settings

Configuration notes for the DACT module, including jumper removal and compatibility.

Polarity Reversal and City Tie Module (PRM) Settings

Configuration notes for the PRM module, including jumper cutting and compatibility.

Module Field Wiring

General Field Wiring Considerations

Best practices for dressing field wires to prevent stress on connections and conduit runs.

Main Fire Alarm Module Terminal Connections

Detailed terminal connections for the main fire alarm board, including circuit types and power ratings.

Circuit Expander Module (CEM) Terminal Connections

Wiring diagrams and terminal connections for the CEM module, covering initiating and indicating circuits.

Relay Module (RY4 or RY8) Terminal Connections

Terminal connections for RY4 and RY8 relay modules, detailing relay contacts and load ratings.

Polarity Reversal and City Tie Module (PRM) Terminal Connections

Terminal connections for the PRM module, including city tie, polarity reversal, and protective device requirements.

Power Supply Connections

Diagram and instructions for connecting the main power supply and batteries to the fire alarm panel.

Wiring Tables

Tables detailing maximum wiring runs and loop resistance for initiating and indicating circuits.

System Checkout

Before Turning Power On

Pre-power-up checklist for modules, wiring, jumpers, and grounding.

Power-Up Procedure

Step-by-step guide for powering up the fire alarm control panel after checkout.

Troubleshooting

Diagnosing common circuit, remote, ground, and battery troubles with the system.

Indicators, Controls, and Operation

Indicators

Description of all panel LEDs, including status, alarm, trouble, and supervisory indicators.

Controls

Explanation of panel switches like System Reset, Signal Silence, Fire Drill, and Auxiliary Disconnect.

Operation

Details on how the panel responds to alarms, subsequent alarms, and system events.

Circuit Types

Defines Initiating (Non-Verified, Verified, Water-Flow, Supervisory) and Indicating (Audible/Visual) circuit types.

Module System Configuration

Walk Test Operation

Appendix A: Compatible Devices

Appendix C: Module Specifications and Features

Appendix D: Power Supply & Battery Calculations

Warranty

Gamewell Flex 4 Specifications

General IconGeneral
BrandGamewell
ModelFlex 4
CategoryFire Alarms
LanguageEnglish