User module »DP-HR-U-CON«
Target and user modules (DP-HR-U) · 84
Main power supply Type: Internal power pack
Connection: 1 × IEC plug(IEC-320 C14)
Current consumption: 100 - 240 VAC; 0.5 A - 0.3 A
Redundant
power supply
optional
Type: External power pack
Connection: 1 × Mini-DIN 4 socket (Power In)
Current consumption: 12 VDC; 2.2 A
Casing Material: Anodised aluminium
Dimensions (W × H × D): 210 × 44 × 210 mm
Weight: Approx. 1.3 kg
Operating
environment
Temperature: +5 °C to +45 °C
Air humidity: 20 % to 80 %, non-condensing
Storage
environment
Temperature: -20°C to +55°C
Air humidity: 15 % to 85 %, non-condensing
Conformity CE, EAC, FCC Class B, RoHS