EasyManua.ls Logo

G&D DP-HR-CPU - Page 96

G&D DP-HR-CPU
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User module »DP-HR-U-CON-2«
91 · Target and user modules (DP-HR-U)
Main power supply Type: Internal power pack
Connection: 1 × IEC plug (IEC-320 C14)
Power input: 100 - 240 VAC; 0.6 A - 0.3 A
Redundant
power supply
optional
Type: Portable power pack
Connection: 1 × Mini-DIN 4 socket (Power In)
Power input: 12 VDC; 2.3 A
Casing Material: Anodised aluminium
Dimensions (W × H × D): 210 × 44 × 210 mm
Weight: Approx. 1.3 kg
Operating
environment
Temperature: +5 °C to +45 °C
Air humidity: 20 % to 80 %, non-condensing
Storage
environment
Temperature: -20°C to +55°C
Air humidity: 15 % to 85 %, non-condensing
Conformity CE, EAC, FCC Class B, RoHS
DP-HR-U-CON-2

Other manuals for G&D DP-HR-CPU

Related product manuals