Page 25 of 35 GTLE Error list GTLE Operating Manual
Message-
number
Sensor-/
actuator
Messagetext Reason Action
25 -
Counting sensor cannot be calibrated,
outside the tolerance window. Manual
Counter sensor position does not match the limit
switch position.
Check whether the landing sensor has not triggered by mistake.
Take the lift to the bottom stop and reset the counting sensor in
26 -
Run time monitoring automatic drive has
The lift ride has exceeded the maximum time for
Check the time for the maximum time for automatic driving.
27 M7 Overload vertical up
The current value during vertical travel exceeds
the set maximum value.
Check whether the drive can be moved easily, if this is the case,
check the set limit value.
28 M7 Overload vertical down
The current value during vertical travel exceeds
Check if the actuator can be moved easily, if this is the case
check the set limit value.
29 - Vertical input config fault The configuration for vertical travel is incorrect.
Check whether the inputs for vertical travel (limit switches) are
configured.
30 - Vertical drive contact floor pressed (S14) An obstacle was detected when lowering.
Remove the obstacle and acknowledge the error by driving in
the opposite direction for two seconds
31 - Vertical drive both limit switch active
Both vertical travel limit switches are actuated at
the same time.
Check if a limit switch is stuck.
32 M7 Overload motor ramp up
The current value when the motor ramp is moving
exceeds the set maximum value.
Check whether the drive can be moved easily, if this is the case,
check the set limit value
33 M7 Overload motor ramp down
Der Stromwert bei der Fahrt der Motorklappe
übersteigt den eingestellten Maximalwert.
Check whether the drive can be moved easily, if this is the case,
check the set limit value
34 - Motor ramp input config fault
The configuration for motor ramp travel is
incorrect.
Check whether the inputs for the motor ramp (limit switch,
release input) are configured.
35 - Motor ramp both limit switches active
The two limit switches of the ramp motor are
actuated at the same time.
Check if a limit switch is stuck.