EasyManua.ls Logo

GARDASOFT RC1 Series - Internal Trigger; Safesense; Safepower; Light Characterisation

GARDASOFT RC1 Series
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RC1xx LED Lighting Controllers - User Manual
15
PNP signal
You can connect a PNP open collector
drive to the RC1xx’s input. Use the
connections shown opposite. The PNP
transistor should not pull up to more
than 24V.
If the P ag is set to ‘1’, the RC1xx
output turns on when the driving
transistor turns on. To reverse this,
set the P ag to ‘0’ (see Section 7.2,
“Triggering”).
7.2.2 Internal trigger
You can set the RC1xx to generate its own trigger pulses. The period of
these pulses can be set in increments of 100μs from approximately 10ms
to 5000ms.
You can set the RC1xx to produce a single pulse for testing purpose. This is
set by either a TR1 command (see Section 10.3.3, “General commands”) or
using the web page Trigger button (see Section 9, “Web page conguration
(RC120)”).
7.3 SafeSense
The SafeSense feature of the RC1xx operates automatically. After setting
the rating for the light, the RC1xx senses the light on connection for its type
and characteristics. The unit does not need to sense the light again unless
the light has changed or the RC1xx has been power-cycled.
For further information on this feature, see the application note, APP936 –
SafeSense Technology, available from www.gardasoft.com.
7.4 SafePower
The RC1xx’s SafePower needs no intervention from the user for its
operation. The advantages of SafePower are:
» Heat dissipation in the controller is very low
» The load voltage can be higher than the supply voltage
» High continuous currents can be output with a reduced need for
heatsinking
For further information on this feature, see the application note, APP966 –
SafePower Technology, available from www.gardasoft.com.
7.5 Light characterisation
You can reduce the time it takes for your RC120 controller to reach high
accuracy in time-critical machine vision systems when changing from one
overdrive brightness setting to another. This can be done by instructing the
controller to make current and voltage measurements up to a customer