RC1xx LED Lighting Controllers - User Manual
26
dEL is displayed. Press the SEL button
to set up the pulse delay time (refer to
Section 10.2.6 “Setting time periods”).
Press the SEL button to conrm the period
set.
PUL is displayed. Press the SEL button to
set up the pulse width (refer to Section
10.2.6 “Setting time periods”). Press the
SEL button to conrm the period set.
rEt is displayed. Press the SEL button to
set up the re-trigger time (refer to Section
10.2.6 “Setting time periods”). Press the
SEL button to conrm the period set.
Use the and buttons to set the
Trigger ag: F P is enabled, F-P is disabled.
Press the SEL button.
Use the and buttons to set the Error
Detect ag: F E is enabled, F-E is disabled.
Press the SEL button.
Pulsed operation is set up.
Note: If you set the brightness to more than 100%, the pulse width is
limited to a safe value as described in Section 7, “General description”.
10.2.6 Setting time periods
When the RC1xx requires you to enter a numeric value, the right hand digit
ashes to indicate you can use the and keys to change the value.
To set pulse delay, re-trigger and pulse width values a scheme is used
where the exponent (power of ten) of the value is set. The exponent values
are as follows:
Exponent
value
Number
format
Range of values
E-2 9.99 Values are displayed in seconds from 10ms
to 5 seconds in steps of 10ms.
E-3 999. Values are displayed in milliseconds from
1ms to 999 ms in steps of 1ms.
E-4 99.9 Values are displayed in milliseconds from
0.1ms to 99.9 ms in steps of 0.1ms.