RC1xx LED Lighting Controllers - User Manual
— 28 —
The internal trigger timer is set.
10.2.8 Using the key lock
You can lock the RC1xx front panel keypad so unauthorised users cannot
change the conguration. To do this you can set a numeric code from 0 to
255, which provides moderate protection.
To lock the keypad, press and hold SEL for 1 second and follow the
keystrokes below:
CH1 is displayed.
Use the and buttons to scroll to LOC
and press the SEL button.
To set the lock code, use the and
buttons to scroll to Lc. Press the SEL
button.
Use the and buttons to set a lock
code value from 0 to 255, and press the
SEL button.
The RC1xx keypad is locked.
Note: Setting a lock code does not prevent a cold boot of the RC1xx. A cold
boot clears the lock code.
To unlock the keypad, press and hold SEL for 1 second and follow the
keystrokes below:
LOC is displayed. Keep pressing the SEL
button.
Un is displayed. Press the SEL button.
Use the and buttons to enter the lock
code and press the SEL button.
CH1 is displayed and the RC1xx keypad is
unlocked. If the code entered is incorrect,
LOC is displayed.