RC1xx LED Lighting Controllers - User Manual
38
RC100 RC120
Timing
repeatability
±5µs (delay + pulse up to 60ms), otherwise ±50µs
Switch mode
latency
100µs maximum
Trigger rate 100Hz maximum
Supply voltage
24V DC ±10% regulated
An SELV power supply is required
Dimensions
120mm long x 35mm wide x 101mm high
(excluding DIN xing)
Weight 0.3kg
Mounting DIN rail mount
Operating
temperature
5°C to 50°C
Humidity 95% maximum (non-condensing)
11.2 Restrictions
The following timings and restrictions are applied when commands are
entered. Exceeding these values causes an error to be returned.
The keypad interface prevents invalid values being entered at the
controller.
11.2.1 Continuous mode
The maximum continuous output current is 1A for the RC100 and 1.2A for
the RC120.
11.2.2 Switched mode
The maximum delay from the trigger input changing state to the output
current switching on or o is 100μs.
The maximum output current is 1A for the RC100 and 2A for the RC120.
11.2.3 Pulse mode
The maximum pulsed output current is 1A for the RC100 and 2A for the
RC120.
When you set a delay of 0μs, there is a delay of approximately 4μs. For
pulse widths of 100μs the output voltage and current cannot be measured.