EasyManua.ls Logo

GARDASOFT RC1 Series - Command Summary

GARDASOFT RC1 Series
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RC1xx LED Lighting Controllers - User Manual
36
Set switched mode
This command sets the output to switched mode and allows the
brightness to be set:
RW1,s,w,r
Where:
s = brightness setting in percent (0 to 999)
w = typical pulse width in ms (optional)
r = likely period in ms (optional)
The w and r parameters are optional and should only be used when
the expected pulse width is >100ms and/or the period is >5 seconds.
w / r gives the expected duty cycle.
Set automatic sensing of light characteristics
Sets the maximum brightness to be used when automatically sensing
the characteristics of the light connected.
PQ1,0
PQ1,m
PQ
Where:
m = maximum expected brightness (50% to 999%)
Setting m = 0 turns o automatic sensing. The PQ command returns
the current maximum brightness for automatic sensing.
10.4 Command summary
Command Example Eect
AW AW Save changes.
CL CL Clear conguration.
GT GT1 Enable Ethernet messages.
GR GR Clear any error conditions.
EY EY65,66 Set web page password to ‘AB’.
VR VR Read the rmware version.
VL VL1,0,0.5 Set the light to 0.5A.
RS RS1,65 Set the unit to 65% brightness
continuously.