For example, for RC12x serial number 12345, IP address 192.168.1.103,
MAC address 00.0B.75.01.80.99 the packet comprises:
Gardasoft,RC12x,012345,000B75018099,C0A80167
9 Web page conguration (RC120)
You can set up the RC120 through its own internal web pages. After
locating your controller on your network, click the Open webpage... button
in GardasoftMaint to take you directly to the RC120’s web pages. You can
also type the controller’s IP address (displayed in GardasoftMaint) into your
web browser, which will display the Main page. GardasoftMaint software is
available from www.gardasoft.com.
9.1 Main page
The main page (shown below) is the rst to open when you access the
RC120’s web pages. This gives the controller’s hardware and rmware
revision levels and the serial number. It also tells you the power being
dissipated and the RC120’s internal temperature.
9.2 Conguration page
The conguration page allows you to set up the lighting parameters,
view the light data, and view the measurements the RC120 makes
during operation. To refresh this page it is important that you click the
Refresh button on the web page () rather than on your web browser.
When conguration changes are submitted, the URL includes the new
conguration, so refreshing the page re-submits the URL.
You can set the mode (continuous, pulsed, or switched), the light’s
brightness and pulse settings. You must click the Submit button to eect
any changes you make.
Click the Refresh button at the bottom of the screen to update the
measurements being taken.