RC1xx LED Lighting Controllers - User Manual
— 35 —
d = 2 to disable the keypad and disallow the unlock code to
be entered on the keypad.
c = the unlock code, which must be a number from 0 to 255.
You can still access the RC120’s settings using Ethernet commands
and through its web pages. The settings of this command are
restored after a power cycle.
10.3.4 Lighting commands
Set the rating of a light
This command sets the current or voltage rating of the light:
VL1,v,c
Where:
v = voltage rating (12 to 24).
c = current rating (10mA to 2A).
Note: If the light is current rated, set the voltage rating to 0; if it is
voltage rated, set the current rating to 0.
Set continuous mode
This command sets the output to continuous mode and allows the
brightness to be set:
RS1,s
Where:
s = brightness as a percentage (0 to 100).
Set pulse mode
This command sets the output to pulse on a trigger input:
RT1,p,d,s,r
Where:
p = pulse width in milliseconds (0.1 to 100).
d = delay from the trigger pulse in milliseconds (0 to 100).
s = brightness setting in percent (0 to 999).
r = re-trigger delay in milliseconds ( 0.1 to 999). This
parameter is optional and if not set, the minimum
allowed re-trigger time is set.
Note: An error message is returned if the brightness setting requires
a greater current than the maximum current output or if the
combination of pulsed width and brightness is not allowed under the
limitations of the unit.