RC1xx LED Lighting Controllers - User Manual
37
Command Example Eect
RW RW1,50 Set the unit to 50% switch mode.
RT RT1,3,4,50 Set the unit to 3ms pulses, delayed by
4ms, at 50% brightness.
RE RE1,6 Set the unit to ignore lighting errors and
make its trigger input active low.
TT TT1,100 Set the internal trigger to operate every
100ms.
KB KB1,23 Disable the keypad buttons on the front
panel. Set the unlock code to 23.
TR TR1 Generate one trigger pulse.
ST ST Show the unit’s conguration details.
11 RC1xx reference information
This section of the user manual contains information about the RC1xx’s
specication, ratings. You can nd further information in Section 11.2,
“Restrictions”, Section 11.3, “Event codes”, and Section 11.4, “Error codes”.
11.1 Specications and ratings
RC100 RC120
User interface Pushbutton
Ethernet and
Pushbutton
Output channel One constant current output with SafeSense
Output current
Up to 1.0A continuous
and1.0A pulsed
Up to 1.2A continuous
and 2.0A pulsed
Output voltage 0V to 32V
Pulsed output
average power
25W maximum
Trigger input
Smart input compatible with 3V-24V, TTL, NPN, and
PNP. Input impedance 8kΩ nominal.
Pulse timing From 100µs to 100ms in steps of 100µs.
Delay from
trigger to pulse
Maximum 10µs xed latency plus user adjustable
steps of 100µs to a maximum of 100ms.