RC1xx LED Lighting Controllers - User Manual
27
Follow the keystrokes below to enter numerical data into the RC1xx using
the scheme shown.
E-2 is displayed. Press the SEL button.
Use the and buttons to select the
required value in steps of 10ms. Press the
SEL button.
Use the and buttons to scroll to E-3
to enter time values from 1ms to 999ms.
Press the SEL button.
Use the and buttons to select the
required value in steps of 1ms. Press the
SEL button.
Use the and buttons to scroll to
E-4 to enter time values from 0.1ms to
99.9ms. Press the SEL button.
Use the and buttons to select the
required value in steps of 0.1ms. Press the
SEL button.
10.2.7 Setting the internal trigger timer
You can set an internal trigger timer when the RC1xx is in pulse mode.
When set, the RC1xx triggers with the same delay and pulse width already
set up as described in Section 10.2.5, “Setting up pulsed operation”.
External triggering remains enabled.
Ensure the RC1xx is set to pulsed operation. To set the period of the
internal trigger timer, press and hold SEL for 1 second, and follow the
keystrokes below:
CH1 is displayed. Press the SEL button.
Use the and buttons to scroll to FrE
and press the SEL button.
OFF is displayed. Use the and
buttons to scroll to ON to set up the
internal trigger. Press the SEL button.
Set up the internal trigger timer as
described in Section 10.2.6 “Setting time
periods”. Press the SEL button.