RC1xx LED Lighting Controllers - User Manual
39
Because of this, fault detection is disabled and the following conditions
apply:
» For pulse currents greater than 0.5A, the duty cycle is restricted to 1%.
» For pulse currents less than or equal to 0.5A , the duty cycle is restricted
to 10%.
11.3 Event codes
On receipt of a GT1 command, the RC120 sends event messages over its
Ethernet link when a light is connected or an error occurs. The message
format is:
Evt1,<event code>
Some event codes are displayed on the RC120’s front panel; these are
shown in red.
Event
number
Reason
1 to 127 An error has occurred. See Section 11.3, “Event codes”.
128 A light has been connected and is working.
129 A light has been connected but does not have a current
or voltage rating.
130 FAT A over temperature error has occurred.
131 FAC An over current error has occurred.
132 An error has occurred while autosensing the rating of
the light.
138 SafePower train-up has completed.
139 SafePower train-up has failed or been cancelled.
140 In switch mode, the light has been turned o because
the duty cycle is too high.