RTxxx LEDlighting controllers - User Manual
Exponent
value
Multiplier Number
format
Range of values
E-2 0.01 9.99
Values are displayed in
seconds from 10ms to 5s in
steps of 10ms.
E-3 0.001 999.
Values are displayed in
milliseconds from 1ms to
999ms in steps of 1ms.
E-4 0.0001 99.9
Values are displayed in
milliseconds from 0.1ms to
99.9ms in steps of 0.1ms.
E-5 0.00001 9.99
Values are displayed in
milliseconds from 0.01ms
to 9.99ms in steps of
0.01ms.
E-6 0.000001 999.
Values are displayed in
microseconds from s to
999μs in steps of s.
Note: The permitted range of values for pulse delay, pulse width, and
retrigger time is given in Section 13, Reference information, or as
limited by the operating conditions of the light.
Follow the keystrokes below to enter numerical data into the RT200
using the above scheme:
E-2
is displayed. Press the
SEL
button to enter time values
from 10ms to 5s.
Use the p and q buttons to select
the required value in steps of
10ms. Press the
SEL
button.