RTxxx LEDlighting controllers - User Manual
PQ
Where:
c = output channel (1 to 2,4 or 8, depending on model)
m - maximum expected brightness (50% to 999%)
Setting m = 0 turns off automatic sensing. The PQcommand
returns the current maximum brightness for automatic sensing.
Set continuous mode
The output is set to continuous mode at a percentage of full
brightness.
RSc,s
Where:
c = output channel (1 to 2, 4 or 8, depending on model)
s = setting in percent (s = 0 to 100)
Set switched mode
The output is set to switched mode at a percentage of full
brightness.
RWc,s,w,r
Where:
c = output channel (1 to 2, 4 or 8 depending on model)
s = setting in percent (s = 0 to 100)
w = typical pulse width in ms (optional)
r = likely period in ms (optional)
The w and r parameters are optional and should only be used
when the expected pulse width is >100ms and/or the period is
>5 seconds. w/r gives the expected duty cycle.
Set selected mode
The output is set to selected mode with two brightness settings.
RUc,s,t
Where:
c = output channel (1 to 2, 4 or 8, depending on model)
s = brightness 1 setting in percent (s = 0 to 100)
t = brightness 2 setting in percent (t = 0 to s)
61