Page 81
8MISCELLANEOUS
Resetting to Factory Defaults
When resetting the GardTec 800 Series to factory defaults several levels of resetting
are available, these are:-
a) Pressing 1, 9, YES, NO during initial power up will revert the Master Code
and Engineer Code (not locked engineer code) back to factory defaults.
b) Pressing 3, 7, YES, NO during initial power up will revert all system settings
back to defaults with the exception of the User Names and Zone Descriptors.
c) Pressing 4, 6, YES, NO during initial power up will revert all system settings
back to factory defaults.
d) Pressing 5, 5, YES, NO during initial power up will revert all system settings
to factory defaults and will also set the comms options up for GardTec Remote.
ie Modem On; No Return. For commissioning systems for use with
GardTec Remote use this option.
To effect a reset of the factory defaults:-
1) Remove all power from the system for at least ten seconds
2) Apply power to the control panel (mains power)
the display will show for example:-
(Display will differ dependant on panel)
3) Whilst this display is showing (the first eight
seconds) press the keys shown in a, b or c
for the reset required, the display will show:-
This may show for several minutes.
4) The display will then show:-
Temporary access may be gained to the factory defaults by removing Lk6 (Reset) on
the main PCB, the link must be replaced before any programming is commenced, this
option will have no effect if the engineer code is locked.
GardTec 840 v 1.0
Please Wait
< < < < UN-SET > > > >
01 Jan 00: 00: 01