Page 89
New Log Events
Two new log events have been added with the implementation of Point ID these are:-
Alarm Abort
The LCD display will show "Alarm Abort" along with the time and date whilst the LED
will show " AA "
Test Call
The LCD display will show "Test Call Sent" along with the time and date whilst the LED
display will show " tC "
Access to programming the Point ID event actions is gained through the "Program
Channels " options. After D1 & D2 and the polarity options have been programmed the
following new options will be presented for programming.
Note: All these options are defaulted to off and should be turned on as
required.
Set Alrm Unset PA
24Hr E/E 12Hr Bat
Tamp AC LF Alert
Fire W/D Duress
Zone Remove Alrm-Restore Zone Exclude PA Restore
AC-Restore LF-Restore After Alarm
After-Alarm Abort-Call
If the After Alarm option is turned on Point ID reports for all options are sent
regardless of whether they are turned on or off following the first alarm event. This will
continue until an Set/Unset event takes place. Note: Alrm=On must be programmed for
this option to work.
Note: Options that are turned on will send messages regardless of alarm status.
Note: Power-Fail refers to Aux Fuse fail and will reported as Lo-Batt to the central
station.
Note: Part-Sets will be reported as Armed Stay to the central station
Note: Output Module tampers will be reported as Expansion Module Tamper to the
central station.
GardTec 872
Appendix 1
872.qxd 05/11/2003 15:01 Page 89