Page 90
GardTec 872 Series
Engineer Code Entered
New Log Event of Engineer Code Entered has been added.
Digi Functions
Programming W
ith Point ID
All normal Digi functions should be programmed as usual with the exception of the
following items that have no function with Point ID protocol.
O/C Channel Select
Restore Report Channel Select
Input Mapping and Polarity
580 Re-mapping
Tone Security Option
The option of Tone Security has been added to the ProDigi. This option is only
applicable when the ProDigi is being used in Point ID mode. When the option is set to
'Tone Security = High' a tone test will occur after any command is used (e.g Set,
Unset, Code Entry). This is in addition to the Tone Test using the Tone Test Time
option.