Page 95
b) Scenario Unlocking the initial entry door disables all means of conformation
6.4.3 DD243:2002.
Event 1 System Set
Event 2 Entry Door Unlocked
Confirmed Alarms Disabled
Event 3 Open Entry Door (entry time starts)
Event 4 Entry Time Expires (inc Entry Time 2)
Unconfirmed Alarm Transmitted
Event 5 Any subsequent zones triggered
No Confirmed Signals Transmitted
Or
Event 1 System Set
Event 2 Entry Door Forced Open (entry time starts)
Event 3 Entry Time Expires (inc Entry Time 2)
Unconfirmed Alarm Transmitted
Event 4 non entry/access Zone Triggered
Event 5 Second non entry.access Zone Triggered
Confirmed Transmitted
To achieve the above
Confirm on entry = On
ET Mode = Door Lock
Door Lock Zone programmed as ET
c) Scenario Opening the initial entry door disables all means of conformation
6.4.4 DD243:2002.
Event 1 System Set
Event 2 Entry Door Opened (entry time starts)
Confirmed Alarms Disabled
Event 3 Entry Time Expires (inc Entry Time 2)
Unconfirmed Alarm Transmitted
Event 4 Any subsequent zones triggered
No Confirmed Signals Transmitted
To achieve the above
Confirmed on entry = Off
GardTec 872
Appendix 1
872.qxd 05/11/2003 15:01 Page 95