Page 53
490X Engineer’s Reference Guide
Choose from the following settings.
No Return Communication to the panel is from GardTec Remote via
Patch Lead or PC Modem.
Return PC The panel will ring the PC back on the number the PC has passed
to the panel.
Return
#1 or #2 The panel will ring back the PC on the #1 or #2 number programmed
into the panel.
Return #1 Only The panel will ring back the PC on the #1 number programmed
into the panel.
Return #2 Only The panel will ring back the PC on the #2number programmed
into the panel.
From Site Only Remote Access will be initialised by the user On-Site.
Off Modem Functions are disabled.
35) Press No until the required setting is displayed
then press Yes. The display will show:-
This option may be used when when the panel is on a shared line and GardTec
Remote is also used.
36) Press No until the required setting is displayed
then press Yes. The display will show:-
You may continue to program other Modem options if required. For the purpose of this
Step by Step Guide.
37) Press 0 (zero). The display will show:-
38) Press Yes. The display will show:-
Double Ring
= Off
Program Comms
Functions ?
Comms = Off
Keypad Lock = Off
In-Use Text = Off
490X 1.qxd 11/07/2006 12:32 Page 53