SECTION 12 – ANNUNCIATIONS
& ALERTS
MFD & PFD Message Advisories
Message Comments
DATA LOST
– Pilot stored data was
lost. Recheck settings.
The pilot profile data was lost. System reverts to default pilot profile and settings.
The pilot may reconfigure the MFD & PFD with preferred settings, if desired.
XTALK ERROR
A flight display
crosstalk error has occurred.
The MFD and PFD are not communicating with each other. The G1000 system
should be serviced.
PFD1 SERVICE
– PFD1 needs service.
Return unit for repair.
The PFD and/or MFD self-test has detected a problem. The G1000 system should
be serviced.
MFD1 SERVICE
– MFD1 needs
service. Return unit for repair.
MANIFEST
– PFD1 software
mismatch, communication halted.
The PFD and/or MFD has incorrect software installed. The G1000 system should
be serviced.
MANIFEST
– MFD1 software
mismatch, communication halted.
PFD1 CONFIG
– PFD1 config error.
Config service req’d.
The PFD and/or MFD configuration settings do not match backup configuration
memory. The G1000 system should be serviced.
MFD1 CONFIG
– MFD1 config error.
Config service req’d.
SW MISMATCH
– GDU software
version mismatch. Xtalk is off.
The MFD and PFD have different software versions installed. The G1000 system
should be serviced.
PFD1 COOLING
– PFD1 has poor
cooling. Reducing power usage.
The PFD and/or MFD is overheating and is reducing power consumption by
dimming the display. If problem persists, the G1000 system should be serviced.
MFD1 COOLING
– MFD1 has poor
cooling. Reducing power usage.
PFD1 KEYSTK
– PFD1 [key name] Key
is stuck.
A key is stuck on the PFD and/or MFD bezel. Attempt to free the stuck key by
pressing it several times. The G1000 system should be serviced if the problem
persists.
MFD1 KEYSTK
– MFD [key name] Key
is stuck.
CNFG MODULE
– PFD1 configuration
module is inoperative.
The PFD1 configuration module backup memory has failed. The G1000 system
should be serviced.
PFD1 VOLTAGE
– PFD1 has low
voltage. Reducing power usage
The PFD and/or MFD voltage is low. The G1000 system should be serviced.
MFD1 VOLTAGE
– MFD1 has low
voltage. Reducing power usage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Garmin G1000 Columbia 350 and is the answer not in the manual?

Garmin G1000 Columbia 350 Specifications

General IconGeneral
AircraftColumbia 350
Display TypeLCD
Display Resolution1024 x 768 pixels
Operating Temperature-20°C to +55°C
Display Size (PFD and MFD)10.4 inches
Power Supply28 VDC
GPS ReceiverWAAS-capable
NavigationVOR, ILS, GPS
DatabaseJeppesen
InterfaceARINC 429, RS-232
Air Data ComputerIntegrated
AHRSIntegrated