Chapter 4: Testing and troubleshooting
96 Concord 4 Installation Manual
Codes System event
555 Phone/sensor test
888 System trouble condition
999 System in alarm
Table 16 below describes pager sensor/zone number and user number report codes.
Table 16: Pager sensor/zone code and numbers
Code Sensor/zone or user number
000 System event not caused by a zone or user
001–096 Sensor/zone numbers 1 to 96
600–829 Regular user codes 0 to 229 used
830-837 Partition master code used
838-845 Partition duress code used
846 System master code used
847 Installer code used
848 Dealer code used
850 Quick arm used
851 Keyswitch sensor used
852 System armed Itself (during service or power-up)
Outputs and sirens
You should test all outputs (onboard and SnapCard) to verify configuration
programming.
Note: Be sure to contact the central monitoring station before activating outputs that
trigger from an alarm condition.
To test outputs:
1. Contact the central monitoring station to inform them you are testing the system.
2. Verify that all wiring at the panel and output devices is correct.
3. Activate the appropriate device to trigger each output as programmed.
4. Verify that each output responds according to the programmed configuration
number. For outputs that trigger sirens, verify that the correct alarm sounds are
produced from these sirens (see
Table 17 on page 97).