Chapter 4: Testing and troubleshooting
106 Concord 4 Installation Manual
Display is blank.
Check that panel is powered up.
Check for touchpad power and/or incorrect bus wiring, opens, or shorts.
Check the touchpad brightness setting. (See the user-programming Options menu
on page 108.)
Touchpad buttons don’t beep when pressed.
Check for touchpad power and/or incorrect bus wiring, opens, or shorts.
Check that key beeps option is set to on. (See the Accessory modules - bus device
settings on page 93.)
Speaker issues
Speakers don’t sound alarms.
Speaker output has shut down because panel detected terminal 7 or 8 is shorted
to ground. Disconnect panel AC and battery backup power. Locate short and
correct. Apply panel AC and backup battery power and retest.
Alarm is in partition 2 to 6 and speaker is connected to panel terminals 7 and 8,
which activate only for partition 1 alarms.
Siren issues
Piezo sirens connected to SnapCard, or onboard (panel) outputs 1 and/or 2 don’t
produce any alarm sounds.
Check for incorrect wiring between siren and panel, and correct where necessary.
Output has not been configured (set up) to activate sirens. Enter program mode
and configure output. (See Accessory modules - bus device settings on page 93.)
Check for correct output partition assignment.
Check that your wires are connected to the appropriate terminals:
Output 1 (exterior) uses terminals 9 (positive) and 13 (ground).
Output 2 (interior, follows status beeps) uses terminals 11 (positive) and 10
(ground).
Hardwired zone issues
System doesn’t go into alarm when zone is tripped.
System is disarmed. Arm system and then trip the zone.