Chapter 3: Programming
Concord 4 Installation Manual 37
Clear memory Clearing memory deletes all existing programming information (except the
dealer code).
Note: Clearing the memory erases onboard hardwired zone factory
programming.
To clear panel memory:
1. With the system in program mode, press A or B until the display shows
CLEAR MEMORY.
2. Press #. The display shows ENTER CODE TO CLEAR MEMORY.
3. Enter the four-digit installer or dealer code (if programmed) and press #.
After about 5 seconds, the system restarts and the panel scans the bus to
learn all bus devices. If the system doesn’t respond as shown, repeat the
process.
Exiting programming After all installer/dealer programming is completed, exit programming mode.
To exit programming mode:
1. Press * until the display shows SYSTEM PROGRAMMING.
2. Press A or B until the display shows EXIT PROGRAMMING READY.
3. Press #. The touchpad displays the time and date.
Tier 2 programming menus
Table 10 below shows the tier 2 system programming menus. Where applicable, the
setting name is followed by the (shortcut) and [default].
Table 11: System programming menus
Security Global
Downloader code (0000) [12345]
Installer code (0001) [4321]
Dealer code (0002) [****]
Access code lock (0003) [On]
Ptn security (0004) [On]
Multi ptn arm (0005) [None]
Keychain tp ptn (0006)
Partition
Account number (0010 to 0060) [00000]
Quick arm (0011 to 0061) [Off]
Quick exit (0012 to 0062) [Off]
Exit extension (0013 to 0063) [On]
Keyswitch sensor (0014 to 0064) [None]
Keyswitch style (0015 to 0065) [Transition]
Duress code (0016 to 0066) [****]

Table of Contents

Other manuals for GE Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 and is the answer not in the manual?

GE Concord 4 Specifications

General IconGeneral
Zones96
Partitions6
User Codes230
Power Supply16.5 VAC, 40 VA
Wireless CompatibilityCompatible with GE wireless sensors
KeypadsUp to 8
Outputs2 onboard, expandable
Event Log512 events
Backup Battery12VDC, 7AH
CommunicationPhone line, optional cellular or IP

Related product manuals