Appendix B: Reference tables
124 Concord 4 Installation Manual
Sensor group characteristics
Table 24 below shows what the sensors on your Concord 4 system do. Every sensor is
assigned to a group, and this table specifies those groups and functions. Every device
must be assigned to one of these groups.
Table 24: Sensor group characteristics
# Name Application Alarm Delay
Restoral
Supervisory
CS Report
Chime (Level)
Active levels
00 Fixed
panic
24-hour audible fixed
emergency buttons.
Police Instant 1,2,3
01 Portable
panic
24-hour audible portable
emergency buttons.
Police Instant 1,2,3
02 Fixed
panic
24-hour silent fixed
emergency buttons.
Silent Instant 1,2,3
03 Portable
panic
24-hour silent portable
emergency buttons.
Silent Instant 1,2,3
04 Fixed
auxiliary
24-hour auxiliary sensor,
such as Pendant Panic or
holdup button.
Auxiliary
Instant 1,2,3
05 Fixed
auxiliary
24-hour auxiliary
emergency button. Siren
shutoff confirms CS report.
Auxiliary
Instant 1,2,3
06 Portable
auxiliary
24-hour portable auxiliary
alert button.
Auxiliary
Instant 1,2,3
07 Portable
auxiliary
24-hour portable auxiliary
button. Siren shutoff
confirms CS report.
Auxiliary
Instant 1,2,3
08 Special
intrusion
Special belongings, such as
gun cabinets and wall safes.
Police Instant 1,2,3
09 Special
intrusion
Special belongings (i.e. gun
cabinets and wall safes.)
Police Standard
1,2,3
10 Entry/
exit delay
Entry and exit doors that
require a standard delay
time.
Police Standard
2,3
11 Entry/
exit delay
Garage doors and
entrances that require an
extended delay time.
Police Extended
2,3

Table of Contents

Other manuals for GE Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 and is the answer not in the manual?

GE Concord 4 Specifications

General IconGeneral
Zones96
Partitions6
User Codes230
Power Supply16.5 VAC, 40 VA
Wireless CompatibilityCompatible with GE wireless sensors
KeypadsUp to 8
Outputs2 onboard, expandable
Event Log512 events
Backup Battery12VDC, 7AH
CommunicationPhone line, optional cellular or IP