Chapter 3: Programming
52 Concord 4 Installation Manual
Phones - downloader phone settings
Phone number
Shortcut: 01090
Default: None
Use this setting to enter the phone number of an offsite computer that can
be used to program the panel through the phone line. Phone numbers can
be 1 to 24 digits long, including pauses or * and # characters.
Call-waiting services should be disabled to prevent interrupting panel
communication to the downloader. To program a dialing prefix that disables
call waiting, see the call wait cancel setting under the “Phone options -
global settings”
below.
To delete a downloader phone number, with the display showing PHONE
NUMBER (current number), press D to erase the number. The display shows
PHONE NUMBER_.
Phone options menu
A phone interface/voice module must be installed for the system to use these
settings (except line fail delay).
Phone options - global settings
Phone test
Shortcut: 02000
Default: On
This setting determines if you can test the communication from the panel
to the central station or a pager by entering 8, code, 2 (#, 8, code, 2 from a
touch tone phone).
Automatic phone test
Shortcut: 02001
Default: Off
This setting determines if the panel sends a phone test automatically to
the central station or a pager on a predetermined schedule. (See Phone
test freq. and Next phone test under “
Timers -global settings” on page 55).
Automatic test reset
Shortcut: 02002
Default: On
This setting determines whether the automatic phone test interval is reset
after any successful report to the central monitoring station. (See Phone
test freq. and Next phone test under “
Timers -global settings” on page 55).
When this feature is on, the panel considers any successful report to the
central monitoring station to be a successful phone test. Thus, any panel
report resets the next phone test setting to the phone test frequency
value. The panel only conducts an automatic phone test if no other
reports have been made during the phone test frequency time. Phone test
frequency must be set to 2 or higher for automatic test reset to work.
When this feature is off, an automatic phone test is always conducted
according to the schedule of the phone test frequency setting, even if the
panel makes other reports to the central monitoring station during that
time.

Table of Contents

Other manuals for GE Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 and is the answer not in the manual?

GE Concord 4 Specifications

General IconGeneral
Zones96
Partitions6
User Codes230
Power Supply16.5 VAC, 40 VA
Wireless CompatibilityCompatible with GE wireless sensors
KeypadsUp to 8
Outputs2 onboard, expandable
Event Log512 events
Backup Battery12VDC, 7AH
CommunicationPhone line, optional cellular or IP