Chapter 3: Programming
Concord 4 Installation Manual 49
Phones - central station phone 1 to 3 settings
Phone number
Shortcut: 01000, 01010,
and 01020
Default: None
Use this setting to program the central station receiver phone number.
Phone numbers can be 1 to 24 digits long, including pauses or *and #
characters.
The phone menus are not accessible if a dealer code is programmed and
the installer code is used to enter installer programming mode. To access
these menus when a dealer code is programmed, you must enter installer
programming mode using the dealer code. Call-waiting services should be
disabled to prevent interrupting panel communication to the central
monitoring station. To program a dialing prefix that disables call waiting,
see the call wait cancel setting under the menu “
Phone options - global
settings”
on page 52.
To delete a central station phone number, with the display showing
HONE
NUMBER (current number), press D. The display shows PHONE NUMBER _.
High level reports
Shortcut: 01001, 01011,
and 01021
Default: On (1),
Off (2 and 3)
When this setting is on, the following conditions report to the central station:
• Fire, police, auxiliary, and duress alarms
• No activity
• Receiver failure (or jam)
• Tamper conditions, including zone tampers and system tamper (40
incorrect key presses or touchpad supervisory)
• Entering or exiting sensor test mode
• Phone test
Low level reports
Shortcut: 01002, 01012,
and 01022
Default: On (1),
Off (2 and 3)
When this setting is on, the following nonalarm conditions report to the
central station:
• Force armed
• Hardwired zone trouble (open or short)
• Supervisory (wireless devices)
• Low battery (wireless devices)
• Phone test
• Other nonalarm related conditions
Exception reports
Shortcut: 01003, 01013,
and 01023
Default: Off
When this setting is on, the panel reports to the central station if the system
is not armed or disarmed at the specified schedule times.
Open/close reports
Shortcut: 01004, 01014,
and 01024
Default: Off
This setting determines whether opening and closing reports are sent to the
central station. When turned on, the panel sends a closing report when the
system is armed and an opening report when the system is disarmed.
To use this feature, the opening reports and closing reports settings under
the “
Reporting menu” on page 59 must be turned on for that partition.